Table 5. Remote Programming Mode Commands - Continued
OP
CODE
(HEX)
MNEMONIC/DESCRIPTION COMMAND/ACKNOWLEDGEMENT
BA BEEPRD
Selects magnetic card read
annunciation mode.
COMMAND: BAp<CR>
BA = Op Code
p = annunciation mode select
<CR> = terminate command (0D hex)
Annunciation selection:
A = beep on good read
B = beep on bad read
C = beep on good and bad read
D = no beep
Annunciation beep frequency for good read is
2000 Hz and for a bad read is 500 Hz.
ACKNOWLEDGEMENT: NONE
BB CDCONT
Determines when cash drawer
status is sent; on demand or when
a change occurs.
COMMAND: BBp<CR>
BB = Op Code
p = selection control
<CR> = terminate command (0D hex)
Selection Control:
A = send on change or transition
B = send on poll command "BC"
ACKNOWLEDGEMENT: NONE